Actisol® Commercial Units

Actisol® Commercial Units2025-03-26T19:37:29+00:00

Commercial Unit – General Information

The Actisol® Commercial Unit mixes a low volume of insecticide with a high volume of air, atomizing the mixture in a special nozzle. The atomization nozzle produces a high proportion of ideally-sized insecticide particles in a continuous high volume air stream. The aerosol penetrates further to reach target insects in the most hidden recesses of cracks, crevices, and voids. This improved penetration is DEEP HARBORAGE pest control.

Commercial Units – PDF Downloads2025-03-06T17:22:35+00:00
Commercial Units – Features2025-03-06T17:22:06+00:00

Features

  • Durable low maintenance design

  • Open Architecture

  • 100 PSI Capable Air Chuck

  • 50’ Hose

  • Ideal for Large Commercial Accounts

  • Professional High Tech Image

  • 1 Year Warranty

Commercial Units – Technical Info2025-03-06T17:21:37+00:00

Technical Info

  • Length: 18″

  • Width: 21″

  • Height: 34″

  • Weight (empty): 48 lbs.

  • Weight (full): 57 lbs.

  • Shipping Weight: 70 lbs.

  • Tank Capacity: 80 oz.

  • Discharge Hose Length: 50ft.
  • Spray Output: 0.56 oz./minute @ 15psi

  • Operating Pressure (liquid): 15 – 30 psi
  • Operating Pressure (air): 35 psi
  • Droplet Size (average): 10 micron
  • Droplet Size (range): 2.4 – 25+ micron

  • Motor: 115 VAC, 60 Hz, 3.9amps

  • Compressor Type: oil-less rocking piston

Commercial Units – Applications2025-03-06T17:21:15+00:00

Applications

  • Deliver Aerosol / Residual Products

  • Deliver Aerosol / Residual Products

  • Food Processing Plants
  • Hospitals
  • Nursing Homes
  • Amusement Parks
  • Hotels

  • Perfect for Sensitive Situations

Commercial Units – Configurations2025-03-06T17:20:49+00:00

Configurations

  • 110 vac w/ 18″ Wand
    Product Code: B290400
  • 110 vac w/ 18″ Wand / Q.D. *
    Product Code: B290400-18QD
  • 220v 50/60hz w/ 18″ Wand
    Product Code: B290700

  • 220v 50/60 hz w/ 18″ Wand / Q.D. *
    Product Code: B290700-18QD

* Q.D. = Quick Disconnect

Preparations and Guidelines When Making ULV Aerosol Applications

(Mallis Handbook of Pest Control, Ninth Edition)

  • Everyone in the treatment area must wear an approved respirator during treatment and when re-entering a treated area when the aerosol may still be present.
  • Turn off all pilot lights or sources of open flame. Ventilation systems and air moving systems should be turned off. Appliances that routinely create high heat should be turned off. Computers and other electrical equipment should be turned off, covered, or removed from the treatment area.
  • All non-pest management personnel must leave the treatment area. Cover or remove ornamental plants. Cover and seal all aquariums. Aquarium filters must be shut off and not turned back on until the aerosol is no longer present. Pets, including exotic pets (birds, amphibians, reptiles, arachnids) must be removed. Re-entry for exotic pets is not recommended for a period of 24 hours.
  • All exposed food must be removed or placed in containers that will prevent contact with the insecticide. Food preparation utensils and surfaces must be covered or cleaned thoroughly before reuse.
  • Close and lock all entry ways. Professionals may want to consider posting warning signs on doors opening into the treatment site.
  • Open all doors, cabinets, storage areas, and drawers in the treatment area.
  • Before reoccupation, thoroughly ventilate treatment area.
  • Do not use gasoline-powered equipment in grain mills, flour mills, grain storage, or grain processing areas. Grain/Flour dust may be highly explosive. Electric powered units must be certified as explosion proof for these sites. Check with manufacturers for details on certification.

Click on the image below for a larger view.

Note:On mobile phones you can scroll this table below left and right.

No. Item Description Buy Online
30 8020030 Aluminum Cart with Tank Buy Online
31 8020040 Compressor Buy Online
32 300123 16/3 STJW Extension Cord – 25′ Buy Online
33 8010033 Plastic Hose Clamp Buy Online
34 8020034 Compressor Mount Isolator with hardware (each) Buy Online
35 8020035 Compressor Intake Filter Complete Buy Online
37 8020037 1/4″ NPT X 1/4″ Tubing Swivel 90° PTL Buy Online
38 8010038 1/4″ Plastic Tubing Buy Online
39 8010039 1/8″ NPT Moisture Filter Buy Online
40 810040 1/8″ Hex Nipple Buy Online
41 8020041 1/4″ Male Branch Tee Buy Online
42 8020042 100 PSI Pressure Relief Valve Buy Online
43 8010043 1/8″ NPT Regulator Buy Online
44 8020044 1/8″ NPT Viton Check Valve Buy Online
45 8010045 1/9″ Street Elbow Buy Online
46 8020046 1/8″ NPT Male X 1/4″ Tubing PTL Buy Online
47 8020047 Manifold Mount Bracket with Hardware Buy Online
48 800048 Threaded & Ported Tank Cap (specify course or fine) Buy Online
49 8010049 1/8″ Ferruless Tubing Fitting Buy Online
51 8020051 1/8″ NPT X 1/4″ Tubing Swivel 90° PTL Buy Online
52 8020052 1/8″ NPT Female Cross Buy Online
53 8020053A Coiled Hose for Air Chuck Buy Online
54 8010054 Regulator Mount Nut Buy Online
55 8020055 1/4″ Clamp on Air Chuck Buy Online
56 8020056 Back Mount 0-160 Gauge Buy Online
58 8020058 Back Mount 0-30 Gauge Buy Online
59 8020059 1/8″ NPT On/Off Ball Valve Buy Online
60 8020060 Manifold Mounting Kit with 2 brackets & 4 Bolts Buy Online
61 8020061 50′ Red Twin Tubing Buy Online
62 8010061 1/8″ NPT x 1/4″ Compressor Elbow Buy Online
63 300063 1/8″ NPT Push Button Pressure Release Valve Buy Online
64 8020064 Tank Drain Valve Assembly Buy Online
65 8020065 8″ Wheel Buy Online
66 8020066 1 1/2 ” Long Nipple Buy Online
67 8020067 Wheel Cap Lock Buy Online
68 8020068 Spring Guard for Coiled Hose Buy Online
70 300070 “O” Ring for Tank Cap Buy Online
71 8020069 1/4″ NPT X 1/4″ Compression Buy Online
73 8010056 Shock Absorber Footer with Hardware (each) Buy Online
74 300064 Drop In Tank Filter Buy Online
75 300075 Tank Cap Complete Buy Online
78 8020075 Manifold Complete Buy Online
79 8020082 Feed-Thru On/Off Switch Buy Online
98 300098 1/8″ NPT X 1/8″ HB – 90 Buy Online
Go to Top